The measurement of shift average exposures to oxides of nitrogen

Two sampling attachments* have been designed for measuring shift average concentrations of nitrogen dioxide and nitric oxide. These can be used with dust samplers so that NOx concentrations may be measurcd simultaneously with dust concentrations. The analysis procedure used is that of LEVAGGI et al(1973). Laboratory and field evaluations of the sampling attachments and the analysis proadure arc described. The preparation of standard mixtures of NO2 in air is also discussed and a comparison is made betwun NO2 in air mixtures produced by permeation tubes and cylinders of NO in nitrogen.

Publication Number: P/077

First Author: Dodgson J

Other Authors: Robertson A , Wood JD

Publisher: Oxford University Press,Oxford University, Oxford,Oxford

Download Publication

COPYRIGHT ISSUES

Anyone wishing to make any commercial use of the downloadable articles on this page should contact the publishers of the journals. Please see the copyright notices on the journals' home pages:

Permissions requests for Oxford Journals Online should be made to: [email protected]

Permissions requests for Occupational Health Review articles should be made to the editor at [email protected]