The focal length method of measuring deposited liquid droplets

An extension to the work of May is presented which is used for the sizing of liquid droplets by the focal length method. Tables are given from which the spread term α and the contact angle θ can be read directly. The effects of various surface preparations on contact angle are given for di-(2-ethylhexyl-sebacate droplets deposited on glass surfaces.