Pneumoconiosis Field Research: Environmental conditions at Fryston Colliery, 1969
This report tabulates respirable dust concentrations and compositions for the period January, 1969 to March, 1970 at Fryston Colliery. As in 1968 dust measurements were made using the M.R.E. Gravimetric Sampler, Type 113A.Information regarding seams worked, outputs, methods of working and dust suppression is presented in a series of face charts, together with the associated dust concentrations.Fryston Colliery, a mechanised colliery, had a mean coalface respirable dust concentration of 5.4 mg/m3. The mean ash content was 46.3 per cent and the mean quartz content was 6.6 per cent (0.36 mg/m3 concentration).
Publication Number: TM/72/12
First Author: Howe JW
Publisher: Edinburgh: Institute of Occupational Medicine
COPYRIGHT ISSUES
Anyone wishing to make any commercial use of the downloadable articles on this page should contact the publishers of the journals. Please see the copyright notices on the journals' home pages:
- Annals of Occupational Hygiene
- Occupational and Environmental Medicine
- American Journal of Respiratory Cell and Molecular Biology
- QJM: An International Journal of Medicine
- Occupational Medicine
Permissions requests for Oxford Journals Online should be made to: [email protected]